Gas Protector Relay
- Model and Description
- UK-202F: Protectorelay for Combustion Safety Control & Automatic Operation of Gas burners with flame rod (current sensor). Valve 2 stage with pilot valve
- UK-202U: Protectorelay for Combustion Safety Control & Automatic Operation of Gas burners with Ultraviolet flame Detector (C7027A or C7035A). Valve 2 stage with pilot valve
- Characteristics
- Power supply: AC-Voltage 200 -240V, Frequency: 50-60 Hz
- Electricity consumption: Below 4.5VA
- Ambient temperature: 20 °C to 60 °C (While not frozen and not dew-drop)
- Standard pre-purge (15s) or special pre–purge (35s)
- Repair and Maintenance
- Cut off electric power immediately and check the cause when the alarm beeps during the operation of device and put the reset-switch on after taking the necessary steps
Instructions
Model |
Description |
UK-202F |
Protectorelay for Combustion Safety Control and Automatic Operation of Gas burners with flame rod (current sensor) Valve 2 stage with pilot valve |
UK-202U |
Protectorelay for Combustion Safety Control and Automatic Operation of Gas burners with Ultraviolet Flame Detector (C7027A or C7035A). Valve 2 stage with pilot valve |
Characteristics
- Power supply: AC 200-240V, 50-60Hz
- Electricity consumption: Below 4.5VA
- Ambient temperature: 20°C to 60°C (While not frozen and not dewdrop
- Special pre-purge setting: Standard pre-purge (15s) or special pre-purge (35s)
SEQUENCE \ MODEL |
UK-202 F(Available special time control) |
UK 202 U(Available special time control) |
Pre-Purge | Standard: 15sec ± 4sec
Special: 35sec ± 5sec |
Standard: 15sec ± 4sec
Special: 35sec ± 5sec |
Post-Purge | 6sec ± 2sec | 6sec ± 2sec |
Safety-Switching | 3sec ± 1sec | 3sec ± 1sec |
Fire Detector Response | Below 1sec | Below 1sec |
Suspect Fire | Below 2sec | Below 2sec |
Post-Purge (Lock-out) | 10–25sec (setting 15sec) | 10-25sec (setting 15 sec) |
Flame Rod | Flame UV TRON | |
Kanthal | C7027, C7035 | |
Fire Detector | Ignition: Over 2uA | Ignition: Over 1.5uA |
Extinction: Below 0.7uA | Extinction: Below 1uA | |
Burner: Over 5uA | Burner: Over 3uA | |
Maximum load | Fan Motor: 250 VA | Fan Motor: 250 VA |
(Use separate relay s/w for more) | IG-trans: 250 VA | IG-trans: 250 VA |
Valve: 100VA | Valve: 100VA | |
Alarm: 100VA | Alarm: 100VA |
Circuit connections with relative devices
- Electric Circuit: Refer to circuit diagram inside products
- Wiring Standard: Use UL AWAG #18
Operation
- Checkpoint:
- Before connecting the device to the electric power line, check carefully whether wires are duly connected
- Use the device within a range of 85 to 110 percent of the nominal voltage
- The device may be wrong operated or damaged when electric voltage is below or over the range
- Reset:
- Put the switch on after waiting for 2 seconds for re-operation
Repair and Maintenance
- Cut off electric power immediately and check the cause when the alarm beeps during the operation of device and put the reset-switch on after taking the necessary steps
- Checking of the device might cause a danger of accidents or its damages. All maintenance and check must be made by qualified personnel with a knowledge of the device